Garages are one of the most humidity-vulnerable spaces in a home. They’re typically uninsulated, poorly ventilated, and subject to moisture from vehicles, weather infiltration, and concrete slab evaporation.
If left uncontrolled, high humidity in a garage leads to: rust on tools and vehicles; mold growth on drywall and stored items; musty odors; peeling paint and warped wood. The most reliable and controllable solution is mechanical dehumidification. This guide explains how to properly dehumidify a garage using the right type of dehumidifier and the correct operating strategy.
1. Why Garages Stay Humid
Common moisture sources:
Concrete slab emission – Concrete continuously releases moisture vapor.
Wet vehicles – Rain and snow introduce gallons of water per week.
Poor insulation – Temperature swings cause condensation.
Air leakage – Gaps around garage doors pull in humid outdoor air.
Lack of HVAC integration – Most garages are not climate-controlled.
Because garages are often semi-conditioned spaces, passive ventilation rarely consistently solves the problem.

2. What Humidity Level Should a Garage Be?
Target Relative Humidity (RH): 45–55%
Above 60% → Mold risk increases significantly
Above 70% → Corrosion accelerates
Below 40% → Over-drying is unnecessary and wastes energy
Use a digital hygrometer to monitor conditions before and after installing a unit.
3. Choosing the Right Dehumidifier for a Garage
A. Capacity (Most Important Factor)
Garages typically require larger capacity units than living spaces.
|
Garage Size |
Recommended Capacity |
|
1-car (200–300 sq ft) |
50–70 pints/day |
|
2-car (400–600 sq ft) |
70–120 pints/day |
|
Workshop / High Moisture |
120+ pints/day |
If you store tools, operate a workshop, or live in a humid climate, size up.
B. Low-Temperature Performance
Garages often drop below 65°F. Standard residential units may:
Enter defrost mode frequently
Lose efficiency
Shut down in cold conditions
Look for:
Low Grain Refrigerant (LGR) technology
Operating range down to ~40°F
Auto defrost with efficient cycling
C. Continuous Drainage
Garage dehumidifiers should always use a gravity drain or a condensate pump discharge, not a bucket.
Options:
Floor drain connection
Sump pit
External condensate pump
This ensures continuous operation without manual emptying. By the way, commercial mobile dehumidifiers from Preair are equipped with a water tank and a drain hose, so users can choose either method to drain water.
4. How to Properly Set Up a Garage Dehumidifier
Step 1: Seal Major Air Leaks
Before running a unit:
Weatherstrip garage door
Seal the bottom door gap
Close unnecessary vents
Otherwise, you’re dehumidifying the outdoors.
Step 2: Proper Placement
Place the unit:
Near the center of the garage
Away from walls (minimum 6–12 inches clearance)
Not directly next to the garage door
Air circulation must remain unobstructed.
Step 3: Set Humidity Target
Set the humidistat to 50% RH initially.
Observe for 48 hours and adjust:
If condensation persists → lower to 45%
If energy use is excessive → raise slightly to 55%
Step 4: Run Continuously in Humid Seasons
Garage humidity fluctuates with the weather. For stable control:
Run a garage dehumidifier with drain hose continuously during spring/summer
Reduce runtime in dry winter climates
Use smart humidity controllers if available
5. Energy Efficiency Considerations
To improve performance and reduce operating cost:
Insulate garage walls and ceiling
Insulate garage door panels
Install a vapor barrier if finishing walls
Use a ceiling fan for air mixing
Keep the garage door closed when possible
Dehumidifiers remove moisture faster in stable environments.
6. Signs Your Garage Needs a Larger Unit
Upgrade if you notice:
RH never drops below 60%
Unit runs 24/7 without cycling
Condensation returns daily
Tools continue rusting
Musty smell persists
Undersizing is the most common failure point in garage moisture control.
7. Dehumidifier vs. Ventilation: Which Is Better?
|
Ventilation |
Dehumidifier |
|
Weather dependent |
Controlled humidity |
|
Can introduce more moisture |
Removes moisture actively |
|
Lower upfront cost |
Higher effectiveness |
|
Inconsistent |
Stable results |
In humid climates, ventilation alone often makes the problem worse.
8. Maintenance Checklist
To keep performance optimal:
Clean the air filter monthly
Inspect the drain line for clogs
Vacuum coils annually
Check humidistat calibration yearly
Poor maintenance reduces moisture removal capacity significantly.
If your garage humidity exceeds 60%, a properly sized high-capacity dehumidifier with continuous drainage is the most effective long-term solution.
For workshops, tool storage, classic cars, or finished garages, investing in a higher-capacity or LGR unit prevents structural damage, rust corrosion, mold remediation costs, and equipment failure. Moisture control in a garage is not about comfort — it’s about asset protection.